Quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures in general dental practice in Englan
Quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures in general dental practice in England, Ireland and Wales in 2009
G. P. KILFEATHER*, C. D. LYNCH † , A. J. SLOAN ‡ & C. C. YOUNGSON §
Journal of Oral Rehabilitation
Early View (Articles online in advance of print)
Published Online: 17 Jan 2010
© 2010 Blackwell Publishing Ltd
ABSTRACT
Summary The aim of this study was to investigate the quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures (RPDs) in general dental practice in England, Ireland and Wales in 2009. Two hundred and ten questionnaires were distributed to 21 laboratories throughout England, Ireland and Wales. Information was collected regarding the quality of written communication and selection of master impression techniques for cobalt chromium partial dentures in general dental practice. One hundred and forty-four questionnaires were returned (response rate = 68%). Alginate was the most popular impression material being used in 58% of cases (n = 84), while plastic stock trays were the most popular impression tray, being used in 31% of cases (n = 44). Twenty-four per cent (n = 35) of impressions were not adequately disinfected. Opposing casts were provided in 81% of cases (n = 116). Written instructions were described as being 'clear' in 31% of cases (n = 44). In 54% of cases (n = 76), the technician was asked to design the RPD. Based on the findings of this study, written communication for cobalt chromium RPDs by general dental practitioners is inadequate. This finding is in breach of relevant contemporary legal and ethical guidance. There are also concerns in relation to the fabrication process for this form of prosthesis, particularly, in relation to consideration of occlusal schemes.
Accepted for publication 13 December 2009
G. P. KILFEATHER*, C. D. LYNCH † , A. J. SLOAN ‡ & C. C. YOUNGSON §
Journal of Oral Rehabilitation
Early View (Articles online in advance of print)
Published Online: 17 Jan 2010
© 2010 Blackwell Publishing Ltd
ABSTRACT
Summary The aim of this study was to investigate the quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures (RPDs) in general dental practice in England, Ireland and Wales in 2009. Two hundred and ten questionnaires were distributed to 21 laboratories throughout England, Ireland and Wales. Information was collected regarding the quality of written communication and selection of master impression techniques for cobalt chromium partial dentures in general dental practice. One hundred and forty-four questionnaires were returned (response rate = 68%). Alginate was the most popular impression material being used in 58% of cases (n = 84), while plastic stock trays were the most popular impression tray, being used in 31% of cases (n = 44). Twenty-four per cent (n = 35) of impressions were not adequately disinfected. Opposing casts were provided in 81% of cases (n = 116). Written instructions were described as being 'clear' in 31% of cases (n = 44). In 54% of cases (n = 76), the technician was asked to design the RPD. Based on the findings of this study, written communication for cobalt chromium RPDs by general dental practitioners is inadequate. This finding is in breach of relevant contemporary legal and ethical guidance. There are also concerns in relation to the fabrication process for this form of prosthesis, particularly, in relation to consideration of occlusal schemes.
Accepted for publication 13 December 2009
Comments