Comparison of occlusal contact errors of 6 chairside CAD/CAM crowns: a self-controlled clinical study
Published: 05 November 2022
Clinical Oral Investigations (2022)Cite this article
Abstract
Objectives
The purpose of this self-controlled clinical study was to evaluate the trueness of occlusal contacts of chairside CAD/CAM crowns fabricated using different ceramic materials.
Materials and methods
Ten volunteers (8 females, 2 males, average aged 20–30) were recruited in this study registered in the Clinical Trials Registry (#NCT05346744). After tooth preparation on tooth 36 or 46, an optical scan unit (CEREC Omnicam, Sirona Dental Systems, Germany) was utilized to perform the intraoral scanning. For each volunteer, 6 crowns were fabricated via the chairside CAD/CAM process (CEREC, Sirona Dental Systems, Germany) using the following materials: InCoris TZI (ZIR), Celtra Duo (CD), e.max CAD (EMA), UP.CAD (UP), Enamic (ENA) and Hyramic (HY). The microhardness of the milled surfaces was measured through a Vickers hardness Tester (HVS-50Z, Trojan, China). Together with the amount of occlusal adjustment, the occlusal contact trueness at both milling and postprocessing stages were quantitatively analyzed by using a high-precision scanner (ATOS, GOM Technologies, USA) and a reverse engineering software (Geomagic Control, 3D Systems, Rock Hill, SC). The times of chairside occlusal adjustment were also recorded. Data were analyzed by one-way analysis of variance (ANOVA) and ANOVA with randomized block design followed by Bonferroni test (p = 0.05).
Results
Significant differences were found in surface microhardness of the materials tested (CD > EMA ~ UP > ENA > HY > ZIR, p < 0.05). Regarding the occlusal contact trueness at milling stage, ZIR showed the lowest (p < 0.05), while no significant difference was found among others (p > 0.05). At postprocessing stage, except for ENA, the occlusal contact trueness of ZIR was significantly lower than that of others (p < 0.05). As for occlusal adjustment amount, ZIR was lower than CD and ENA (p < 0.05). In addition, ENA, HY and ZIR required fewer times of occlusal adjustment than EMA, UP and CD.
Conclusions
The type of chairside CAD/CAM ceramic materials affected the occlusal contact trueness throughout the process of manufacturing and the amount of clinical occlusal adjustment as well. Zirconia exhibited the worst occlusal contact trueness at both milling and postprocessing stages, while the amount of occlusal adjustment was the least, which recommended the least occlusal compensation.
Clinical relevance
For better trueness, different negative occlusal offsets are suggested to be applied in the design process, so as to suit the material of the restoration.